Plumbing Portal
Advertisement:
home   menu    latest news   menu    calendar     menu    blog     menu    buyers guides     menu    media kits     menu    RJ's Tool Bin   menu    store     menu    contact   menu    links    

Search in: EditorialProductsCompanies

Overly Separated
by John Siegenthaler, P.E.
June 19, 2009

ARTICLE TOOLS
EmailEmailPrintPrintReprintsReprintsshareShare



The Glitch

Overview: During the last three years, a new hardware device has been showing up in more American hydronic systems. It’s called a hydraulic separator, and it’s now available in a range of sizes from several manufacturers.

Hydraulic separators provide an alternative to closely spaced tees when the task is to isolate the pressure dynamics of one hydronic circuit from those of another, connected circuit.

Eager to keep up with this new technology, an installer decides to install a hydraulic separator between a boiler and distribution system as shown in the figure below. Some of the load circuits connected to the hydraulic separator are piped “across the headers,” while others are connected with closely spaced tees.  All the load circuits are supposed to operate independently.

Exercise: When the system was turned on, there was very little warmth from the low temperature loads. What’s the problem?


The Fix

A hydraulic separator eliminates the need to use closely spaced tees when connecting load circuits. All load circuits can be piped across the headers. Those headers should be short, and generously sized. This keeps the pressure drop along the length of the header extremely small (e.g., negligible). The slow flow rate along the vertical height of the hydraulic separator adds virtually nothing to this pressure drop. Thus, the differential pressure between the upper and lower headers is essentially zero. Each load connected across the headers is unable to detect the presence of the other load circuits.

Using closely spaced tees downstream of the hydraulic separator adds a second – and totally unnecessary – hydraulic separation between the lower circuits and the hydraulic separator itself. The lower circuits with the mixing valves will only receive heated water when those circuits connected across the header are active. At other times the water returning to the lower header will simply make a right-hand U-turn and be drawn back into the hot port of the mixing valve. The solution is simple: Just pipe all the loads across the headers as shown.

The expansion tank should also connect near the hydraulic separator as shown.

Finally, always put 10 or 12 pipe diameters of straight pipe on the inlet of any circulator to minimize turbulence into the impeller.


John Siegenthaler, P.E.
john@hydronicpros.com
John Siegenthaler, P.E., is principal of Appropriate Designs, a consulting engineering firm in Holland Patent, N.Y., and author of the text “Modern Hydronic Heating.” Visit www.hydronicpros.com for information on new software for hydronic system design and documentation. John is also the contributing editor to PM's monthly "The Glitch & The Fix" column, which offers hydronic troubleshooting solutions in conjuction with the magazine's twice-monthly Radiant & Hydronics eNews newsletter. You can reach John by e-mail at john@hydronicpros.com.

Links

  Comments (0)Post a Comment
 

No HTML or BBCode in comments please.
 


PMmag.com

Visit Plumbing & Mechanical website.


PMEngineer.com

Visit PM Engineer website.


SupplyHT.com

Visit Supply House Times website.


ReevesJournal.com

Visit Reeves Journal website.


Bath and Kitchen Pro

Visit Bath & Kitchen Pro website.


RadiantandHydronics.com

Visit Radiant & Hydronics website.


Radiant + Hydronics eNews
Click the button below to sign up for the Radiant + Hydronics eNews.


Bath & Kitchen Pro eNews
Click the button below to sign up for the Bath & Kitchen Pro eNews.


PVF E-News
Click the button below to sign up for the PVF E-News.


PME E-News
Click the button below to sign up for one of PME's free E-Newsletters.














Water Quality Association
Want to know more about water? Then look no further than WQA's Water Information Library - a new cross-industry database of information consisting of articles from the top industry publications as well as WQA's own extensive technical papers and resources.


College of Product Knowledge CD by Don ArnoldCollege of Product Knowledge CD by Don Arnold

Invest in the best-read series ever published for the Plumbing Industry & the most highly acclaimed product training CD. Knowledge is an investment
Click Here




home   |    latest news   |     calendar   |    blog   |    buyers guides   |    media kits   |     RJ's Tool Bin   |     store   |    contact   |    links